Appendix 2 Remote I/O Signals; List Of Remote I/O Signals - Mitsubishi Electric MELSEC iQ-R Series User Manual

Cc-link ie field network waterproof/dustproof remote i/o module (with safety functions)
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Appendix 2
This appendix lists the remote I/O signals for a master/local module.
The following shows an assignment example of I/O signals with the remote I/O signals of the safety remote I/O module
assigned to the I/O numbers of RX0 to RX4F and RY0 to RY4F.
Remote input (RX) are input signals from the safety remote I/O module to the master/local module.
Remote output (RY) are output signals from the master/local module to the safety remote I/O module.
The remote I/O signals of the safety remote I/O module are assigned as shown below.
Module
Safety remote I/O module
• These signals (RX/RY) are used to control and monitor functions other than the safety functions of the
safety remote I/O module.
• The external I/O signals of the safety remote I/O module are communicated to the master/local module
using the "safety remote I/O signals (SA\X and SA\Y)".
• Do not use these signals in a program that operates the safety functions. If any of the signals is used, the
correct operation of the safety functions of the module cannot be guaranteed.
• When "Link Stop" is performed using the CC-Link IE Field diagnostics and the cyclic transmission is
stopped from the link special relay (SB) or link special register, the input status of RX is held, and thus the
status may differ from the actual status of the module.

List of remote I/O signals

The remote I/O signals of the safety remote I/O module are assigned as shown below.
Remote input
Signal direction: Safety remote I/O module  Master/local
module
Device No.
RX0 to RXF
RX10 to RX1F
RX20 to RX2F
RX30 to RX3B
RX3C to RX3F
RX40 to RX45
RX46 to RX4F
Do not use any "Use prohibited" remote I/O signals. Doing so may cause an accident due to incorrect output
or malfunction.
APPX
108

Appendix 2 Remote I/O Signals

Remote I/O Signals
Remote input (RX)
RX0 to RX4F
Description
Module status area
Error code
Warning code
External input monitor
Use prohibited
Power supply monitor
Use prohibited
Remote output (RY)
RY0 to RY4F
Remote output
Signal direction: Master/local module  Safety remote I/O
module
Device No.
RY0 to RYF
RY10 to RY1F
RY20 to RY2F
RY30 to RY3B
RY3C to RY3F
RY40 to RY45
RY46 to RY4F
Description
Use prohibited