Satec System 295 Installation And Operation Manual page 143

Powermeter & harmonic analyzer
Table of Contents

Advertisement

Table B-4b Analog Output Parameters
Group
Code
H01-H39
hr.U2
H01-H39
hr.U3
H01-H39
hr.C1
H01-H39
hr.C2
H01-H39
hr.C3
H01-H39
hr.Ac
H01-H39
hr.rE
H01-H39
hr.PF
H01-H39
À The parameter window resolution is 7 digits. The parameter limits are as follows:
Vmax (660V input option) = 660 [V] @ PT ratio = 1.0 and Vmax = 144
ratio [V] @ PT ratio > 1.0
Vmax (120V input option) = 144
Imax = 1.2
Iaux max = 1.2
Pmax = (Imax
Pmax = (Imax
or 3LL3
Á Readings with a decimal point are displayed as MW, Mvar, MVA.
 The actual frequency range is 45.0 - 65.0 Hz
Appendix B Programmable Parameters
Parameter
Name
Harmonic H01-H39
L2/L23 phase harmonic voltages (odd harmonics)
Harmonic H01-H39
L3 phase harmonic voltages (odd harmonics)
Harmonic H01-H39
L1 phase harmonic currents (odd harmonics)
Harmonic H01-H39
L2 phase harmonic currents (odd harmonics)
Harmonic H01-H39
L3 phase harmonic currents (odd harmonics)
Harmonic H01-H39
Harmonic total active powers (odd harmonics)
Harmonic H01-H39
Harmonic total reactive powers (odd harmonics)
Harmonic H01-H39
Harmonic total power factors (odd harmonics)
Harmonic H01-H39
×
CT primary current [A]
×
Auxiliary CT primary current [mA/A]
×
×
Vmax
3)/1000 [kW] @ Wiring mode 4Ln3 or 3Ln3
×
×
Vmax
2)/1000 [kW] @ Wiring mode 4LL3, 3OP2, 3dir, 3OP3
Unit
Á
V
V
V
A
A
A
kW
kvar
n/a
×
PT Ratio [V]
Range/scale À
Zero
Full
0
Vmax
0
Vmax
0
Vmax
0
Imax
0
Imax
0
Imax
-Pmax
Pmax
-Pmax
Pmax
-1.00
1.00
135
×
PT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm295