Danfoss VLT AutomationDrive FC 302 Instruction Manual page 96

Low harmonic drive 132–630 kw
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Programming
6.3.13 12-** Ethernet
Par. No.
Parameter description
#
12-0* IP Settings
12-00
IP Address Assignment
12-01
IP Address
12-02
Subnet Mask
12-03
Default Gateway
12-04
DHCP Server
12-05
Lease Expires
12-06
Name Servers
12-07
Domain Name
12-08
Host Name
6
6
12-09
Physical Address
12-1* Eth link par
12-10
Link Status
12-11
Link Duration
12-12
Auto Negotiation
12-13
Link Speed
12-14
Link Duplex
12-2* Process Data
12-20
Control Instance
12-21
Process Data Config Write
12-22
Process Data Config Read
12-23
Process Data Config Write Size
12-24
Process Data Config Read Size
12-27
Master Address
12-28
Store Data Values
12-29
Store Always
12-3* EtherNet/IP
12-30
Warning Parameter
12-31
Net Reference
12-32
Net Control
12-33
CIP Revision
12-34
CIP Product Code
12-35
EDS Parameter
12-37
COS Inhibit Timer
12-38
COS Filter
12-4* Modbus TCP
12-40
Status Parameter
12-41
Slave Message Count
12-42
Slave Exception Message Count
12-5* EtherCAT
12-50
Configured Station Alias
12-51
Configured Station Address
12-59
EtherCAT Status
12-6* Ethernet PowerLink
12-60
Node ID
12-62
SDO Timeout
12-63
Basic Ethernet Timeout
12-66
Threshold
12-67
Threshold Counters
12-68
Cumulative Counters
12-69
Ethernet PowerLink Status
12-8* Oth. Ethernet services
12-80
FTP Server
12-81
HTTP Server
12-82
SMTP Service
12-89
Transparent Socket Channel Port
12-9* Adv. Eth. services
94
Instruction Manual
Default value
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
[0] No Link
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
16 N/A
16 N/A
0 N/A
[0] Off
[0] Off
0 N/A
[0] Off
[0] Off
ExpressionLimit
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
1 N/A
30000 ms
5000.000 ms
15 N/A
0 N/A
0 N/A
0 N/A
[0] Disabled
[0] Disabled
[0] Disabled
ExpressionLimit
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
4-set-up
Change
Conver-
during
sion
operation
index
2 set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
Type
-
Uint8
0
OctStr[4]
0
OctStr[4]
0
OctStr[4]
0
OctStr[4]
0
TimD
0
OctStr[4]
0
VisStr[48]
0
VisStr[48]
0
VisStr[17]
-
Uint8
0
TimD
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint16
-
Uint16
0
Uint32
0
Uint32
0
OctStr[4]
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint32
0
Uint16
0
Uint16
0
Uint16
0
Uint32
0
Uint32
0
Uint16
0
Uint16
0
Uint32
0
Uint8
-3
Uint32
-6
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
-
Uint8
-
Uint8
-
Uint8
0
Uint16
MG37A222

Advertisement

Table of Contents
loading

Table of Contents