Danfoss VLT AutomationDrive FC 302 Instruction Manual page 48

Low harmonic drive 132–630 kw
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

User Interface
Bottom section
always shows the state of the adjustable frequency drive in
status mode.
Top section
Middle section
5
5
Bottom section
Figure 5.5 Bottom Section Status Mode
Display contrast adjustment
Press [status] and [
Press [Status] and [
LEDs:
If certain threshold values are exceeded, the alarm and/or
warning LED lights up. A status and alarm text appear on
the control panel.
The On LED is activated when the adjustable frequency
drive receives power from:
AC line voltage
a DC bus terminal
an external 24 V supply
At the same time, the back light is on. LEDs
Green LED/On: Control section is working.
Yellow LED/Warn: Indicates a warning.
Flashing Red LED/Alarm: Indicates an alarm.
Figure 5.6 LED Status Lights
GLCP keys
Menu keys
The menu keys are divided into functions. The keys below
the display and LEDs are used for parameter set-up,
including choice of display indication during normal
operation.
Status
Figure 5.7 Menu Keys
46
Instruction Manual
Status
43 RPM
5.44 A
25.3 kW
1.4 Hz
2.9%
! Pwr.card temp (W29)
Auto Remote Running
] for darker display
] for brighter display
On
Warn.
Alarm
Quick
Main
Alarm
Menu
Menu
Log
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
[Status]
Indicates the status of the adjustable frequency drive
(and/or the motor) or the filter respectively. On the drive
LCP, three different readouts can be selected by pressing
!
1(1)
the [Status] key:
Five line readouts, four line readouts, or Smart Logic
Control.
Smart Logic Control is not available for the filter.
Use [Status] for selecting display mode or reverting to
display mode from:
quick menu
main menu
alarm mode
Use the [Status] key to toggle single or double readout
mode. Status
[Quick Menu]
Allows quick set-up of the adjustable frequency drive or
the filter and programming of the most common
functions. Quick menu
The [Quick Menu] consists of:
Q1: My Personal Menu
Q2: Quick Set-up
Q5: Changes Made
Q6: Loggings
Since the active filter is an integrated part of the Low
Harmonic Drive, only a minimum of programming is
necessary. The filter LCP displays information about filter
operation such as THD of voltage or current, corrected
current, injected current or Cos ϕ and true power factor.
The Quick Menu parameters can be accessed immediately
unless a password has been created via parameters 0–60,
0–61, 0–65 or 0–66.
It is possible to switch directly between quick menu mode
and main menu mode.
[Main Menu]
Is used for programming all parameters.
The main menu parameters can be accessed immediately
unless a password has been created via parameters 0–60,
0–61, 0–65 or 0–66.
It is possible to switch directly between main menu mode
and quick menu mode.
Parameter shortcut can be carried out by pressing down
the [Main Menu] key for three seconds. The parameter
shortcut allows direct access to any parameter.
MG37A222