Danfoss VLT AutomationDrive FC 302 Instruction Manual page 165

Low harmonic drive 132–630 kw
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Specifications
Surroundings
Enclosure
Vibration test
Relative humidity
Aggressive environment (IEC 60068-2-43) H
Test method according to IEC 60068-2-43 H
Ambient temperature
- with derating
- with full output current (short temperature overload)
- at full continuous output current (24 hours)
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Maximum altitude above sea level with derating
EMC standards, Emission
EMC standards, Immunity
Control card performance
Scan interval
Control card, USB serial communication
USB standard
USB plug
Generic specifications
Maximum parallel filters
Filter efficiency
Typical average switching frequency
Response time (reactive and harmonic)
Settling time - reactive current control
Settling time - harmonic current control
Overshoot – reactive current control
Overshoot – Harmonic current control
Connection to PC is carried out via a standard host/device USB cable. The USB connection is galvanically isolated from the
supply voltage (PELV) and other high-voltage terminals. The USB connection is not galvanically isolated from ground
protection. Use only isolated laptop/PC as connection to the USB connector on the unit or an isolated USB cable/drive.
Protection and features
Temperature monitoring of the heatsink ensures that the active filter trips if the temperature reaches a predefined
level. An overload temperature cannot be reset until the temperature of the heatsink is below the acceptable
values.
If a line phase is missing, the active filter trips.
The active filter has a short circuit protection current rate of 100 kA if properly fused
Monitoring of the intermediate circuit voltage ensures that the filter trips if the intermediate circuit voltage is too
low or too high.
The active filter monitors the line power current as well as internal currents to ensure that current levels do not
reach critical levels. If current exceeds a critical level, the filter trips.
MG37A222
Instruction Manual
5%–95% IEC 721-3-3; class 3K3 (non-condensing) during operation
S test
2
S (10 days)
2
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
+13° to 158°F [-25° to +70°C]
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EN 61800-3, EN 61000-6-1/2,
USB type B "device" plug
IP21, IP54
1.0 g
class kD
max. NA °F [°C]
max. 113°F [45°C]
max. 104°F [40°C]
32°F [0°C]
14°F [-10°C]
3300 ft [1000 m]
10,000 ft [3000 m]
5 ms
1.1 (full speed)
11
4 on same CT set
97%
3.0–4.5 kHz
< 0.5 ms
< 20 ms
< 20 ms
<10%
<10%
163
11