Danfoss VLT AutomationDrive FC 302 Instruction Manual page 106

Low harmonic drive 132–630 kw
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Programming
6.3.21 32-** MCO Basic Settings
Par.
Parameter description
No. #
32-0* Encoder 2
32-00
Incremental Signal Type
32-01
Incremental Resolution
32-02
Absolute Protocol
32-03
Absolute Resolution
32-04
Absolute Encoder Baudrate X55
32-05
Absolute Encoder Data Length
32-06
Absolute Encoder Clock Frequency
32-07
Absolute Encoder Clock Generation
32-08
Absolute Encoder Cable Length
6
6
32-09
Encoder Monitoring
32-10
Rotational Direction
32-11
User Unit Denominator
32-12
User Unit Numerator
32-13
Enc.2 Control
32-14
Enc.2 node ID
32-15
Enc.2 CAN guard
32-3* Encoder 1
32-30
Incremental Signal Type
32-31
Incremental Resolution
32-32
Absolute Protocol
32-33
Absolute Resolution
32-35
Absolute Encoder Data Length
32-36
Absolute Encoder Clock Frequency
32-37
Absolute Encoder Clock Generation
32-38
Absolute Encoder Cable Length
32-39
Encoder Monitoring
32-40
Encoder Termination
32-43
Enc.1 Control
32-44
Enc.1 node ID
32-45
Enc.1 CAN guard
32-5* Feedback Source
32-50
Source Slave
32-51
MCO 302 Last Will
32-52
Source Master
32-6* PID Controller
32-60
Proportional factor
32-61
Derivative factor
32-62
Integral factor
32-63
Limit Value for Integral Sum
32-64
PID Bandwidth
32-65
Velocity Feed-Forward
32-66
Acceleration Feed-Forward
32-67
Max. Tolerated Position Error
32-68
Reverse Behavior for Slave
32-69
Sampling Time for PID Control
32-70
Scan Time for Profile Generator
32-71
Size of the Control Window (Activation)
32-72
Size of the Control Window (Deactiv.)
32-73
Integral limit filter time
32-74
Position error filter time
32-8* Velocity & Accel.
32-80
Maximum Velocity (Encoder)
32-81
Shortest Ramp
32-82
Ramp Type
32-83
Velocity Resolution
32-84
Default Velocity
104
Instruction Manual
Default value
[1] TTL (5V, RS4222)
1024 N/A
[0] None
8192 N/A
[4] 9600
25 N/A
262 kHz
[1] On
0 m
[0] Off
[1] No action
1 N/A
1 N/A
[0] No soft changing
127 N/A
[0] Off
[1] TTL (5V, RS4222)
1024 N/A
[0] None
8192 N/A
25 N/A
262 kHz
[1] On
0 m
[0] Off
[1] On
[0] No soft changing
127 N/A
[0] Off
[2] Encoder 2
[1] Trip
[1] Encoder 1 X56
30 N/A
0 N/A
0 N/A
1000 N/A
1000 N/A
0 N/A
0 N/A
20000 N/A
[0] Reversing allowed
1 ms
1 ms
0 N/A
0 N/A
0 ms
0 ms
1500 RPM
1 s
[0] Linear
100 N/A
50 N/A
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
4-set-up
Change
Conver-
during
sion
operation
index
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
-3
2 set-ups
TRUE
-3
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
-3
2 set-ups
TRUE
-3
2 set-ups
TRUE
67
2 set-ups
TRUE
-3
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
Type
-
Uint8
0
Uint32
-
Uint8
0
Uint32
-
Uint8
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint32
0
Uint32
-
Uint8
0
Uint8
-
Uint8
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint32
0
Uint32
0
Uint16
0
Uint16
0
Uint32
0
Uint32
0
Uint32
-
Uint8
Uint16
Uint8
0
Uint32
0
Uint32
Int16
Int16
Uint32
Uint32
-
Uint8
0
Uint32
0
Uint32
MG37A222