Programming
6.3.11 9-** Profibus
Par.
Parameter description
No. #
9-00
Setpoint
9-07
Actual Value
9-15
PCD Write Configuration
9-16
PCD Read Configuration
9-18
Node Address
9-19
Drive Unit System Number
9-22
Telegram Selection
9-23
Parameters for Signals
9-27
Parameter Edit
9-28
Process Control
6
6
9-44
Fault Message Counter
9-45
Fault Code
9-47
Fault Number
9-52
Fault Situation Counter
9-53
Profibus Warning Word
9-63
Actual Baud Rate
9-64
Device Identification
9-65
Profile Number
9-67
Control Word 1
9-68
Status Word 1
9-70
Edit Set-up
9-71
Profibus Save Data Values
9-72
ProfibusDriveReset
9-75
DO Identification
9-80
Defined Parameters (1)
9-81
Defined Parameters (2)
9-82
Defined Parameters (3)
9-83
Defined Parameters (4)
9-84
Defined Parameters (5)
9-85
Defined Parameters (6)
9-90
Changed Parameters (1)
9-91
Changed Parameters (2)
9-92
Changed Parameters (3)
9-93
Changed parameters (4)
9-94
Changed parameters (5)
9-99
Profibus Revision Counter
Table 6.13
92
Instruction Manual
Default value
0 N/A
0 N/A
ExpressionLimit
ExpressionLimit
126 N/A
1034 N/A
[100] None
0
[1] Enabled
[1] Enable cyclic master
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
[255] No Baud rate found
0 N/A
0 N/A
0 N/A
0 N/A
[1] Set-up 1
[0] Off
[0] No action
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
FALSE
1 set-up
TRUE
2 set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
Type
0
Uint16
0
Uint16
-
Uint16
-
Uint16
0
Uint8
0
Uint16
-
Uint8
-
Uint16
-
Uint16
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
V2
-
Uint8
0
Uint16
OctStr[
0
2]
0
V2
0
V2
-
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
MG37A222