Danfoss VLT AutomationDrive FC 302 Instruction Manual page 88

Low harmonic drive 132–630 kw
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Programming
6.3.6 4-** Limits/Warnings
Par.
Parameter description
No. #
4-1* Motor Limits
4-10
Motor Speed Direction
4-11
Motor Speed Low Limit [RPM]
4-12
Motor Speed Low Limit [Hz]
4-13
Motor Speed High Limit [RPM]
4-14
Motor Speed High Limit [Hz]
4-16
Torque Limit Motor Mode
4-17
Torque Limit Generator Mode
4-18
Current Limit
4-19
Max Output Frequency
6
6
4-2* Limit Factors
4-20
Torque Limit Factor Source
4-21
Speed Limit Factor Source
4-3* Motor Speed Mon.
4-30
Motor Feedback Loss Function
4-31
Motor Feedback Speed Error
4-32
Motor Feedback Loss Timeout
4-34
Tracking Error Function
4-35
Tracking Error
4-36
Tracking Error Timeout
4-37
Tracking Error Ramping
4-38
Tracking Error Ramping Timeout
4-39
Tracking Error After Ramping Timeout
4-5* Adj. Warnings
4-50
Warning Current Low
4-51
Warning Current High
4-52
Warning Speed Low
4-53
Warning Speed High
4-54
Warning Reference Low
4-55
Warning Reference High
4-56
Warning Feedback Low
4-57
Warning Feedback High
4-58
Missing Motor Phase Function
4-6* Speed Bypass
4-60
Bypass Speed From [RPM]
4-61
Bypass Speed From [Hz]
4-62
Bypass Speed to [RPM]
4-63
Bypass Speed To [Hz]
86
Instruction Manual
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
ExpressionLimit
[0] No function
[0] No function
[2] Trip
300 RPM
0.05 s
ExpressionLimit
10 RPM
1 s
100 RPM
1 s
5 s
0 A
ImaxVLT (P1637)
0 RPM
ExpressionLimit
-999999.999 N/A
999999.999 N/A
-999999.999 ReferenceFeed-
backUnit
999999.999 ReferenceFeed-
backUnit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-1
Uint16
-1
Uint16
-1
Uint32
-1
Uint16
-
Uint8
-
Uint8
-
Uint8
67
Uint16
-2
Uint16
-
Uint8
67
Uint16
-2
Uint16
67
Uint16
-2
Uint16
-2
Uint16
-2
Uint32
-2
Uint32
67
Uint16
67
Uint16
-3
Int32
-3
Int32
-3
Int32
-3
Int32
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
MG37A222

Advertisement

Table of Contents
loading

Table of Contents