Outputs (S); Inputs (S) - HEIDENHAIN ND 7000 Operating Instructions Manual

Table of Contents

Advertisement

16

16.6.17 Outputs (S)

Path:
Parameters
Analog output
Analog output is inverted
Smax
Umax
Enable spindle CW
Enable spindle CCW

16.6.18 Inputs (S)

Path:
Parameters
Enable digital movement
commands
Spindle start
Spindle stop
Digital enable inputs
256
The switching functions are available only for units with ID number
1089179-xx.
Settings ► Axes ► S ► Outputs
The switching functions are available only for units with ID number
1089179-xx.
Settings ► Axes ► S ► Inputs
Explanation
Assignment of the analog output according to pin layout
Default value: Not connected
If this function is active, the analog signal is inverted at the
output
Default value: not active
Definition of the Spindle speed attained with Umax
Setting range: 100 rpm ... 10000 rpm
Default value: 2000
Maximum voltage that is output at the analog output in order to
attain Smax
Setting range: 1000 mV ... 10000 mV
Default value: 9000
Assignment of the digital output for the clockwise spindle enable
according to pin layout
Default value: Not connected
Assignment of the digital output for the counterclockwise
spindle enable according to pin layout
Default value: Not connected
Explanation
Use of the digital movement commands
Settings: ON or OFF
Default value: OFF
Assignment of the digital input for the spindle start according to
pin layout
Default value: Not connected
Assignment of the digital input for the spindle stop according to
pin layout
Default value: Not connected
Configuration of the digital inputs for the spindle enable
HEIDENHAIN | ND 7000 | Operating Instructions | 05/2018
Settings | Axes

Hide quick links:

Advertisement

Table of Contents
loading