Restore Settings - HEIDENHAIN ND 7000 Operating Instructions Manual

Table of Contents

Advertisement

17

Restore settings

17.6
Backed-up settings can be restored to the product. The current configuration of the
product is replaced in the process.
A restore can be necessary in the following cases:
During commissioning, the settings are set on a product and transferred to all
identical products
Further information:
After a reset, the settings are copied back to the product
Further information:
Safely removing a USB mass storage device
276
Software options that were active when the settings were backed up
must be activated before restoring the settings.
"Steps for commissioning", Page 94
"Reset all settings", Page 277
Tap Settings in the main menu
Open in the sequence
Service
Back up and restore
Restore settings
Tap Complete restoration
If required, connect a USB mass storage device (FAT32
format) to a USB port of the product
Navigate to the folder containing the backup file
Select the backup file
Tap Select
Confirm successful transfer with OK
The system is shut down
To restart the product with the transferred configuration data,
switch the product off and then back on
Tap File management in the main menu
Navigate to the list of storage locations
Tap Safely remove
The message The storage medium can be removed now.
appears
Disconnect the USB mass storage device
Service and Maintenance | Restore settings
HEIDENHAIN | ND 7000 | Operating Instructions | 05/2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents