Example:
The following MDI block is programmed:
Figure 63: Example – MDI block
A Scaling factor of -0.5 is activated for the X axis. The following MDI block will
therefore be executed:
Figure 64: Example – Execution of an MDI block with scaling factor
216
If the calculated dimensions cannot be attained with the selected tool,
then the execution of the MDI block is aborted.
The scaling factor cannot be changed during execution of an MDI block.