6 Start-up
70
Weekly programming:
"PARAM"
"Set up 2"
Each day can be programmed individually. The following programmes are available
• "Clean": Cleaning trigger by entering the start time
• "Clean Int": Cleaning is carried out at intervals with a defined spacing. This pro-
gramme cannot be started via the binary inputs directly.
• "User": User-defined cleaning programmes (create in programme editor; from Field
NAD1).
Programme sequences (cleaning example)
Monday:
2 x cleaning (at 11:00 and at 18:00) with 120 s. water, of which 60 s. additionally with
cleaner.
Clean every 30 mins. between 18:20 and 24:00 (= 1800 s.) with 120 s. water, of which
60 s. additionally with cleaner.
Clean
Hold
Hold and Hold delay time
60 sec
water
+cleaner
Clean Int
Hold
Hold and Hold delay time
water
60 sec
+cleaner
Measuring
time
18:20
Fig. 28:
Graphic representation of the above example
Required settings according to the example
(bold: to be edited by user):
Field OAA1
Clean
11:00
11:02
Clean
18:00
18:02
Clean Int
18:20
24:00
In this way, each day can be programmed (or copied) individually.
"ChemoClean":
60 sec
+cleaner
60 sec
+cleaner
Meas. time1800 sec
Field OAA2
(with "Clean")
01 Water
60 s
02 +Cleaner
60s
03 Water
0 s
04 Rep. Clean
0x
Mycom S CPM 153
Hold and Hold delay time
60 sec
60 sec
+cleaner
Field OAA2
(with "Clean Int")
01 Water
60 s
02 +Cleaner
60s
03 Water
0 s
Measuring time
1800 s
Endress+Hauser