Commissioning

Designations
S1
Proximity sensor S1
S2
Proximity sensor S2
S3
Proximity sensor S3
V1
Pilot valve 1
V2
Pilot valve 2
Pot.-free
Potential-free contact
Emergency stop
Emergency stop (input circuit)
Feedback loop
Feedback circuit
Safety device
Safety relay unit or safety PLC
Digital output
Digital output
Digital input
Digital input
Standard PLC
Programmable logic controller
Tab. 7 Designations in circuit examples
8
Commissioning
The product does not have its own control logic and must therefore be integrated into the control sys-
tem through appropriate measures.
Graphic display of commissioning è Fig.3.
Proceed as follows to commission the product:
Apply operating pressure p1
Ä The product is now ready for operation and can be actuated.
The filling speed of the pneumatic system can be adjusted with the flow control valve è Fig.2.
9

Operation

Perform a forced switch-off at least once a month if the process-related switching frequency is lower.
10

Maintenance

10.1

Maintenance work

A dirty silencer can extend the time needed for exhausting the system and thus restrict the safety func-
tion.
Check the silencer regularly and replace if necessary.