AC Power Inlet Panel
The optional AC power inlet panel is described here.
AC Power Cord
The AC power cord (
A
rated and permanently mounted to the power inlet panel.
Power Switch/Circuit Breaker
The power switch/circuit breaker (
rocker type actuator switch that will activate or deactivate
the AC power to the system. The power ON position is
marked with the internationally recognized I symbol, the
power OFF position is marked with the 0 symbol. This
power switch also integrates an appropriately sized over-
current protection circuit breaker function in the genera-
tor.
If an over-current condition trips the circuit breaker, it
will automatically switch to the OFF position. If the over-
load current that caused the circuit breaker to trip is due
to a transient condition, the circuit breaker can be reset by
switching the actuator back to the ON position. If when
resetting the circuit breaker after it has tripped, it imme-
diately trips again, there is likely an internal system mal-
function, and the generator will require service.
Do not repeatedly try to reset the circuit breaker. If it
trips, this will only cause more damage to the generator.
Chassis Ground Stud
The chassis ground stud is used to attach a protective
earth ground to the generator. This will aid in the sup-
pression of electrical interference or radio frequency in-
terference (RFI) that is common in an industrial environ-
ment. The chassis ground stud is
system grounding is discussed on Page 9.
Dukane Manual Part No. 403-586-02
in Figure 6-2) is appropriately
in Figure 6-2) has a
B
in Figure 6-2. Proper
C
B
LINE VOLTAGE:
A
100-120 Vac
50/60Hz, 10A
120 Volt line cord
Figure 6 - 2 120VAC Power Inlet Panel
Section 6 - Options
PE
C
Page 89

Advertisement

Table of Contents
loading

Table of Contents