Utilities; Placement - Dukane iq series User Manual

Ultrasonic press system
Hide thumbs Also See for iq series:
Table of Contents

Advertisement

iQ
Series Ultrasonic Press System LE User's Manual
Lockout/Tagout
Procedure to use BEFORE making any internal
adjustments to the generator:
1. Push the generator's AC power switch/breaker to the
OFF position.
2. Unplug the generator's electrical cord from its
source.
3. Authorized personnel apply a lockout/tagout
(LOTO) device to the plug end of the generator's
electrical cord. Using a typical clam shell type
LOTO device:
1) Open the clam shell.
2) Place the electrical cord plug end inside
the shell.
3) Close the shell.
4) Secure the shell with its lock, and lock it.
4. Wait a minimum of five minutes for the generator to
discharge its electrical energy.
5. After taking these steps, make the necessary
adjustments to the generator.
Assuming the generator is being put back into service.
Procedure to use AFTER making any internal
adjustments to the generator:
1. Authorized personnel remove the lockout/tagout
device from the plug end of the generator's electrical
cord. Using a typical clam shell type LOTO device:
1)
Unlock the protective shell.
2)
Open the shell, exposing the electrical cord
end.
3)
Remove the LOTO device, and set it aside.
2. Plug the generator's electrical cord into its AC
power source.
3. Push the generator's AC power switch/breaker to the
ON position.
Page 14
Continued from Previous Page

Utilities

Provide for electricity to meet the equipment
specifications as shown in Section 12, Specifications.
contamination or moisture can coat or
clog the transducer. This can result in
premature failure of the transducer.
Air pressure is determined by the
application, transducer power draw
and ambient air temperature.

Placement

Check that enough space has been set aside for the
installation. Equipment dimensions are shown in Section
12, Specifications.
In addition, take extra precautions when the
installation is made in an active seismic region. See
the recommendations for generator installation on the
following two pages.
CAUTION
If transducer cooling air
is used, this compressed
air must be clean, dry and
oil free. Any particulate, oil