Distance Encoder

Purpose
To install and calibrate the distance encoder in order to
accurately measure the distance of thruster travel.
Requirements
Parts
Kit (P/N 438-783) consisting of the following:
• Encoder (two pieces; P/N 625-18),
• Encoder head cable cover bracket, and
• Mounting screws and hardware.
Tools
• Phillips-head screwdriver
• Feeler gauge set (0-.050 inches) or metric equivalent
• 6 inch ruler or metric equivalent
Installation Instructions
Dismantling
1. Facing the front of the press, remove the panel from
the right side of the press. (See Figure 6-7.)
Reassembly
1. Mount the cable cover bracket from the kit and secure
it with flat head screws.
2. Attach the encoder scale to the mounting screw holes
in the right side of the thruster with pan-head screws.
Do not tighten.
3. Remove the back panel from the press and route the
encoder head cable, being careful not to interfere with
the press movement.
4. Connect the encoder cable to the generator connector
J-11 (Encoder).
5. Replace the rear panel on the press.
Dukane Manual Part No. 403-586-02
Right Side Panel
Encoder Scale
Figure 6-7 Distance Encoder Mounting
Section 6 - Options
Encoder
Head
Continued
Page 93