Compressed Air Requirements

For all press/thruster models, Dukane recommends 80-110 psi of clean, dry air.
Maximum available clamping pressure:
Model
Force Generated at
110 psi (lb)
43Q220
540
Table 12- III
Clamping Pressure

AC Power Requirements

T
he press/thruster uses 24VDC @ 2 Amps, obtained from the iQ Series generator to which
it is connected. The AC line voltage and current needed depend on whichever generator has
been chosen for your system. See the table below.
Operating
Generator
Model Number
Frequency
20kHz
20XX120-1X-XX-XX
20kHz
20XX120-2X-XX-XX
20kHz
20XX240-2X-XX-XX
20kHz
20XX360-2X-XX-XX
Table 12- IV
AC Power Requirements
NOTES:
An X used above in the Model Numbers is a "wildcard" character meaning any valid character code combination.
Maximum line current requirement is specified at the minimum nominal AC line voltage and the rated power level.
Page 150
Standard Air Cylinder
Diameter (in)
2.50
Overload
Input AC Power Requirements
Power
Nominal AC Volt
Ratings
@ Maximum RMS Current
(Watts)
1200
100-120V 50/60 Hz @ 15 Amps
1200
200-240V 50/60 Hz @ 8 Amps
2400
200-240V 50/60 Hz @ 15 Amps
3600
200-240V 50/60 Hz @ 25 Amps
North America/
Japan
AC Outlet Rating
15 Amps
30 Amps
Dukane Manual Part No. 403-586-02