All of the digital output status signals on this connector,
are isolated (signals are not referenced to generator chassis
ground). When a status output signal is activated, it will
sink current (500mA Max. sourced by a 24VDC supply)
to isolated common. In automation terms, the outputs are
NPN (sinking) and would drive a PNP (sourcing) input
that is referenced to the Isolated Common pin.
System Outputs Connector Pinout
The
SYSTEM OUTPUTS
D-subminiature 25 circuit female) connector. Connector
pin numbers for this connector are shown in Figure 3-10.
The male connector on the cable is a mirror image of the
panel mounted connector and is shown in Figure 3-11.
Table 3-III lists the signal names. Detailed descriptions
are listed in System Outputs Signal Descriptions that fol-
low. To assist with custom automation system wiring and
assembly, the wire color coding for the system outputs
cable is listed in Table 3-III.
System Outputs Signal Descriptions
Pin 1 (+22V Power Supply)
This pin can supply +22VDC at up to 250mA to power
the user's automation controls.
Pin 2 (Not Used)
Pin 2 is an open connection.
Pin 3 (+22V Power Ground)
Pin 3 is the 22VDC return and is tied to the system chas-
sis ground.
Dukane Manual Part No. 403-586-02
Continued from Previous Page
connector is a DB-25F (standard
Pin 4 (Programmable Status Output 1)
Pin 4 is a digital status output that can be reprogrammed
and assigned to other system status signals (from the
available selections) from the front panel Advanced
Settings menu.
Pin 5 (Programmable Status Output 2)
Pin 5 is a digital status output that can be
reprogrammed and assigned to another system status
signal (from the available selections) from the front
panel Advanced Settings menu
Pin 6 (Ultrasound Active Status Output)
Pin 6 is a digital status output that activates when the
system is delivering ultrasonic power to the load at-
tached to the ultrasound output connector. This output
will be an open circuit when the ultrasound output is off.
Pin 7 (Any Fault Status Output)
Pin 7 is a digital status output that activates whenever
any fault condition is detected that inhibits ultrasound
output and normal system operation. This output will
be an open circuit when no system fault conditions are
detected. In the case of an overload, this output stays
active until the start of the next cycle or until cleared
using the front panel keypad or system input Pin 12
(System Latch Reset input).
Generator faults that will activate the Any Fault output:
• Overload (Average, Peak, or Frequency)
• Overtemperature Fault
• System Power Fault
Pin 8 (Press Trigger Status Output)
Pin 8 is a digital status output that activates when the
specified trigger type has occurred. It will remain ac-
tive until the end of cycle. This output will be an open
circuit when a trigger condition hasn't been detected.
Section 3 - Installation
.
Continued
Page 23