Rear Panel Layout Overview - Dukane iq series User Manual

Ultrasonic press system
Hide thumbs Also See for iq series:
Table of Contents

Advertisement

Rear Panel Layout Overview

This section provides an overview of the generator rear
panel layout, which includes panel areas dedicated to var-
ious standard system functions and options that are avail-
able. Figure 3-5 illustrates a typical panel layout.
B
I
0
LINE VOLTAGE:
200-240 Vac
50/60Hz, 15A
A
Figure 3-5
Typical iQ LE Generator Rear Panel Layout
AC Power Inlet Panel
IEC Power Inlet Connector – Attaches to an IEC style
A
power cord.
Power Switch – Circuit Breaker – Used to switch sys-
B
tem power ON and OFF.
Chassis Grounding Stud – Chassis connection for a
C
protective earth ground.
The System I/O Panel
System Input Connector (J2) – Connections for sys-
D
tem control input signals.
System Output Connector (J3) – Connections for sys-
E
tem status output signals.
Ultrasound Output Connector (J1) – Coaxial high
F
voltage connection to ultrasonic stack.
Configuration Port Connector (J4) – Digital control
G
port to modify system parameters.
Dukane Manual Part No. 403-586-02
-WARNING-
POWER LINE OUTLET
MUST BE GROUNDED.
DISCONNECT LINE POWER
BEFORE REMOVING COVER.
DUKANE CORP
ST. CHARLES IL 60174
PE
MADE IN U.S.A.
U.S. PATENT 5,880,580
OTHER PATENTS PENDING
C
H
J5 THRUSTER
J11 ENCODER
J6 BASE/ABORT
Options Module Panel
Expansion Boards
H
Press Interface Module (See NOTE below.)
K
Shown in the example above are these ports:
The press interface module is available
in several different configurations.
See Section 6, Options for more
information about the Press Interface
Module.
Section 3 - Installation
K
D
E
SYSTEM INPUTS
J2
SYSTEM OUTPUTS
J3
ULTRASOUND
J1
CONFIGURATION
J4
F
G
J6 - Base/Abort
J5 - Thruster
J11 - Encoder
NOTE
Page 17