iQ
Series Ultrasonic Press System LE User's Manual
AC Power Inlet Panel
The standard AC power inlet panel is described in this sec-
tion.
IEC AC Power Inlet Connector
The IEC AC power inlet connector mounted on the system
AC power inlet panel requires a properly configured IEC
compliant power cord, which enables worldwide system
operation by simply changing the power cord.
Low profile systems are equipped with a 10 amp rated IEC
inlet connector. The high profile systems include a 16/20
amp rated IEC inlet connector. 120VAC and 3600/4800W
systems include a non-detachable power cord.
An appropriately rated power cord must be securely at-
tached to the welding system's IEC inlet connector. If the
correct power cord configuration is not included with the
system for the local AC power outlet at your location, an
appropriate IEC power cord should be available from a
local electrical parts supplier. Note that the system under-
voltage lockout will inhibit system operation if a North
American power cord configured for 120V is connected to
the system. A minimum of 200V is required for the system
to operate.
Power Switch/Circuit Breaker
The power switch/circuit breaker has a rocker type actua-
tor switch that will activate or deactivate the AC power
to the system. The power ON position is marked with the
internationally recognized I symbol, the power OFF posi-
tion is marked with the 0 symbol. This power switch also
integrates an appropriately sized over-current protection
circuit breaker function in the generator.
If an over-current condition trips the circuit breaker, it will
automatically switch to the OFF position. If the overload
current that caused the circuit breaker to trip is due to a
transient condition, the circuit breaker can be reset by
switching the actuator back to the ON position. If when
resetting the circuit breaker after it has tripped, it imme-
diately trips again, there is likely an internal system mal-
function, and the generator will require service.
Do not repeatedly try to reset the circuit breaker. If it trips,
this will only cause more damage to the generator.
Page 18
Chassis Grounding Stud
The chassis grounding stud is used to attach a protec-
tive earth ground to the generator. This will aid in the
suppression of electrical interference or radio frequency
interference (RFI) that is common in an industrial envi-
ronment. The chassis ground stud is
Proper system grounding is discussed on Page 9.
I
0
LINE VOLTAGE:
200-240 Vac
50/60Hz, 10A
PE
C
Figure 3-6 IEC AC Power Inlet Connector
System I/O Panel
The standard system I/O panel is described in this sec-
tion. See Figure 3-7.
System Inputs Connector
The
SYSTEM INPUTS
tem I/O panel includes connections for all of the basic
system control input signals, that will typically come
from an automated control system. The cable attached to
this connector includes all of the available system con-
trol signals, which will be controlled by an output card
or output port on the automation controller.
The user can determine which signals to use for each
particular welding application, but there must be at least
one connection to this connector in order to activate the
ultrasound output. All of the input signals on this con-
nector are electrically isolated (signals are NOT refer-
enced to chassis ground) and can be driven from an au-
tomation controller output that is either sinking (NPN)
or sourcing (PNP), depending upon how the isolated
common connection is terminated. Signals are activated
when the voltage difference between the signal and the
isolated common pin is 24V.
All inputs sink or source 10mA of current from a 24VDC
power supply.
Dukane Manual Part No. 403-586-02
C
in Figure 3-6.
connector mounted on the sys-
Continued