iQ
Series Ultrasonic Press System LE User's Manual
OPERATE
Name of setup being edited if in
Automation Mode, Otherwise the
setup is in use.
Operating Mode
Figure 5-48 Operate Screen - I
When the generator is powered up, there is an initial
screen that shows system information. That is followed by
the Operate screen as shown in Figure 5-48 above.
This is a display only screen. The values displayed are
from the last weld cycle. The operator can access this
screen by pressing the OPERATE hot key.
The process characteristics shown in Figure 5-48 above
are the ones where part limits have been enabled, or are
those that have been selected to display.
As an example, here is a list of all possible characteristics
that a distance press could have. (If distance is not sup-
ported, then these characteristics would not be available.)
Downstroke Time
Downstroke Distance
Trigger Delay Time
Trigger Delay Distance
Time
Peak Power
Energy
Page 72
Online/Offline/E-Stop Status
SETUP #01
AUTO 01
PART COUNT
WELD TIME
ENERGY
PEAK POWER
DISTANCE
PROCESS
STATISTICS
PRE
AMP
WELD
WELD
Weld Distance
Weld End Position
Hold End Position
Hold Time
Hold Distance
Total Cycle Time
Total Cycle Distance
POST
LIMITS
SETUPS
OPERATE
WELD
Process Characteristics
System Power
Output Level
ONLINE
0
0.000s
0.0J
0W
0.000IN
LIVE
Dukane Manual Part No. 403-586-02