iQ
Series Ultrasonic Press System LE User's Manual
Emergency Stop (Abort)
Switch
A red Emergency–Stop (E-STOP) switch is located in the
center of the base as shown in Figure 4-12. The emer-
gency stop switch must be in its reset position before the
operate switches will function.
To reset the Emergency Stop, twist the large red button
about 45 degrees to the right, which will cause the button
to spring out. This is shown in Figure 4-15.
The abort switch applies 24 VDC power to the thruster/
press. Pressing the abort switch causes the generator to:
• Immediately turn off the ultrasound,
• Remove electrical power from the press, and
• Initiate a software abort sequence.
Base Status Display
The function of the display is to indicate one of three
status conditions of the press:
READY
- When the abort switch is pulled out, the
green READY status light indicates that power is
applied to the press and it is ready for operation.
ABORT
- When the abort switch is pushed in, the
red ABORT status indicator illuminates. Press opera-
tion is no longer possible.
IN CYCLE
- When both activation switches are
pressed, the IN CYCLE display of the status indicator
is ON for the duration of the finger switch activation.
Page 52
Figure 4-15 Setting and Resetting the E–STOP
Any modifications to the
Emergency Stop Switch (also
known as the E-STOP or Abort
Switch) circuit must comply
with all OSHA and ANSI requirements .
Compliance with all local building and
electrical codes is also required .
Dukane Corporation does not assume
any responsibility or liability for circuit-
ry modifications made by the customer
or by any third party manufacturer .
Dukane Manual Part No. 403-586-02
WARNING