Changing Stack Components

Stack Removal

Before removing the stack, perform the following
steps:
1. Activate the E-STOP (Abort) switch on the
front of the press base.
2. Power down the generator.
These two steps are necessary to ensure that no
power will be accidently applied while removing
the stack.
3. While supporting the stack with one hand,
loosen the two or four socket-head screws that
secure the stack access door.
4. If the door has two screws, swing it open. If it
has four screws, remove it completely.
5. Pull the stack forward and down until the
transducer clears the electrical contact. Refer
to Figure 7-2.
6. Lift the stack out of the housing.
Figure 7-2
Stack Removal
Dukane Manual Part No. 403-586-02
Section 7 - Acoustic Stack/Fixture Setup
CAUTION
The stack access door on
the press/thruster holds
the stack components in
the stack housing. Hold
the stack by the HORN or the exposed
part of the BOOSTER when removing
or installing the access door. This will
prevent the stack from falling out and
being damaged.
NOTE
When changing or inspecting any of
the stack components, ALWAYS re-
move the stack from the thruster.
CAUTION
There may be an electri-
cal charge stored in the
transducer. To avoid any
electrical shock, do not
touch the contact button when re-
moving the stack.
CAUTION
The stack may be hot