iQ
Series Ultrasonic Press System LE User's Manual

WELD

The WELD menu seen in Figure 5-23, shows the message
that is displayed if the MODE was set to AUTOMATED
PROBE.
The WELD menu shown in Figure 5-24 has the MODE set
to iQ CONTROLLED PROBE.
The menu shown in Figure 5-25 at the right appears when
the MODE is MANUAL or AUTOMATED PRESS, and
DISTANCE is not supported by the generator.
The menu shown in Figure 5-26 at the right appears when
the MODE is MANUAL or AUTOMATED PRESS.
ENERGY has been selected, and a value for energy will
be entered.
Page 64
WELD CONTROLLED BY AUTOMATION
PRE  
AMP  
WELD  
WELD  
Figure 5-23 Weld Menu, Mode: Automated Probe
>
TIME
0.000s
PRE  
AMP  
WELD  
WELD  
Figure 5-24 Weld Menu, Mode: iQ Controlled Probe
>
TIME
0.000s
PRE  
AMP  
WELD  
WELD  
Figure 5-25 Weld Menu, Mode: Manual/Automated
Press, Distance not Supported
ENERGY
>
0J
MAX TIME
0.000s
PRE  
AMP  
WELD  
WELD  
Figure 5-26 Weld Menu, Mode: Manual/Automated
Press, Energy Selection
Dukane Manual Part No. 403-586-02
POST  
LIMITS  
SETUPS  
OPERATE  
WELD  
TIME
ENERGY
USE +/- TO SELECT
PRESS ENTER TO CHANGE
POST  
LIMITS  
SETUPS  
OPERATE  
WELD  
TIME
ENERGY
GROUND DETECT
USE +/- TO SELECT
PRESS ENTER TO CHANGE
POST  
LIMITS  
SETUPS  
OPERATE  
WELD  
TIME
ENERGY
GROUND DETECT
PRESS ENTER TO ACCEPT
PRESS CANCEL TO ABORT
POST  
LIMITS  
SETUPS  
OPERATE  
WELD  