Note that a simple switch closure (relay contact) connect-
ed to a control input can not activate the input without
adding an external power supply to power the input. Add-
ing jumper connections to pins available on the System
Inputs connector, can configure switch closure inputs to
operate referenced to generator chassis ground (non-iso-
lated), without adding a separate power supply, if desired.
Refer to Application Note AN507 (Automation Interface
Guidelines) at http://www.dukane.com/us/DL_ApplDa-
ta.asp for wiring diagrams of example applications.
System Inputs Connector Pinout
The
SYSTEM INPUTS
density D-subminiature 15 circuit female) connector.
Connector pin numbers for this connector are shown in
Figure 3-8. The male connector on the cable is a mirror
image of the panel-mounted connector and is shown in
Figure 3-9. Table 3-II lists the signal names and descrip-
tions, with more detailed descriptions that follow. The
wire color coding for the system input cable is listed in
Table 3-II, to assist with custom automation system wir-
ing and assembly.
Dukane Manual Part No. 403-586-02
Continued from Previous Page
connector is a HD-15F (high
Figure 3-7
System I/O Panel (Standard Panel Shown)
Refer to Section 6, Options for information