Hot Keys - Dukane iq series User Manual

Ultrasonic press system
Hide thumbs Also See for iq series:
Table of Contents

Advertisement

iQ
Series Ultrasonic Press System LE User's Manual

Hot Keys

(8)
Each of the eight hot keys under the display, when
pressed, brings up one of these portions of the generator
menu:
AMP - Adjust amplitude for Weld, Pre-Trigger
and Afterburst portions of the weld cycle.
PRE-WELD - Select operating Mode; disable
or set Pre-Trigger values; and, select Trigger type,
trigger maximum time, and trigger delay.
WELD - Choose weld type (time, energy, dis-
tance, position or ground detect).
POST WELD - Set parameters for Hold and
Afterburst parts of the cycle.
LIMITS - Set which weld characteristics to be dis-
played, and which will have their bad part or suspect
part limits enabled.
SETUPS - Choose setup control, name setups,
copy and erase setups.
OPERATE - This is a display-only screen
showing cycle data from the last cycle. Only those
selected to be displayed or have process limits set
will be shown.
LIVE - This is a display-only screen showing real
time Amplitude, Power, Operating Frequency,
and Position. (If position is not supported, it is not
displayed.)
See the next section, OPERATION for more detail on
the functions of these hot key sub-menus.
Page 42
NOTE
The white bar along the bottom of the LCD
display indicates what Hot Key menu is
being displayed.