Reconditioning Stack Components
10. Reexamine the interface surface and repeat Steps
6 through 9 until most of the contaminate has been
removed. This should not take more than 2 or 3
complete rotations of the part being reconditioned.
11. Reassemble and install the stack, using the procedure
in Section 7 of this manual. Recheck the power supply
tuning.
Torque Values
See Section 7, Acoustic Stack/Fixture Setup for torque
values:
Table 7-I - Stud Torque Values
Table 7-II - Horn/Booster Torque Values
Table 7-III - Replaceable Tip Torque Values
Dukane Manual Part No. 403-586-02
Continued from Previous Page
NOTE
Thread deformation may occur
if the studs are overtightened.
Removal of the stud could
damage the threads in the
horn. If this occurs, re-tap the
horn threads and replace the
stud with a new one. Use studs
recommended by Dukane.
NOTE
Overtightening stack com-
ponents may result in horn/
booster studs loosening and
unexplained overloads.
Section 8 - Stack Maintenance