Rfi Grounding - Dukane iq series User Manual

Ultrasonic press system
Hide thumbs Also See for iq series:
Table of Contents

Advertisement

RFI Grounding

iQ Series generator provides the operating power
The
and power returns. Make sure the generator is grounded
properly.
In addition to the safety considerations, proper grounding
is essential for the effective suppression of RFI (Radio
Frequency Interference). Every generator contains a RFI
filter which blocks noise on the AC power line from enter-
ing the generator control circuitry. This filter also prevents
ultrasonic RFI from being fed back into the AC power line.
If you experience problems with RFI from the press, run
an additional grounding wire from the press base ground-
ing stud to the nearest grounded metal pipe or equivalent
earth ground by means of a ground clamp. Use at least 14
AWG wire for the connection to the press base.
Dukane Manual Part No. 403-586-02
To minimize electrical noise
and eliminate ground cur-
rents, ground the chassis
as shown. Use a STAR con-
figuration (illustrated below).
Do not DAISY CHAIN the
grounds.
Chassis Grounding
Stud
#14 Gauge
Recommended protective
earth ground connection
Solid Wire
wire color: green or green
with yellow stripe.
Earth
Ground
Section 3 - Installation
CAUTION
Fixed Probe Mount
or 2nd Chassis
Grounding Stud
Stranded or
3rd Chassis
Grounding
Stud
Page 27