Dukane iq series User Manual page 28

Ultrasonic press system
Hide thumbs Also See for iq series:
Table of Contents

Advertisement

iQ
Series Ultrasonic Press System LE User's Manual
Pin
1
+22V
2
Power Ground
3
Remote Setup Selection Bit 0 Input
4
Remote Setup Selection Bit 1 Input
5
Remote Setup Selection Bit 2 Input
6
Remote Setup Selection Bit 3 Input
7
Remote Setup Selection Bit 4 Input
8
Ultrasound Activation/Cycle Start Input
9
Not Used
10
Front Panel Control Lock Input
11
Press Inhibit for Hand Probes
12
System Latch Reset Input
13
Isolated Common
14
Not Used
15
Automation Cycle Stop Input
Table 3-II Generator Input Signals (J2)
System Inputs Signal Descriptions
Pin 1 (+22V)
This pin can supply +22VDC at up to 250mA to power the
user's automation controls.
Pin 2 (Power Gnd)
Pin 2 is the 22VDC return and is tied to the system chassis
ground.
Pin 3 (Remote Setup Selection Bit 0 Input)
Pin 3 is the Remote Setup Selection Bit 0, which is the
least significant bit used to select different welding setups
with an automation control system.
Pin 4 (Remote Setup Selection Bit 1 Input)
Pin 4 is the Remote Setup Selection Bit 1, which is the
second least significant bit used to select different welding
setups with an automation control system.
Page 20
Continued from Previous Page
Signal Name
Cable Color Code
BLK
WHT
RED
GRN
ORN
BLU
WHT/BLK
RED/BLK
GRN/BLK
Not Used
ORN/BLK
Not Used
BLU/BLK
Hand Probe
BLK/WHT
RED/WHT
GRN/WHT
BLU/WHT
5
5
15 14 13 12 11
15 14 13 12 11
Figure 3-8
HD-15F, Generator Input Connector
Figure 3-9
HD-15M, Generator Input Cable
Connector
Signal Option Requirements
4
3
2
1
4
3
2
1
10
10
6
6
1 2 3 4 5
6
10
11 12 13 14 15
Dukane Manual Part No. 403-586-02