Compressed Air Requirements; Ac Power Requirements - Dukane i220 User Manual

Iq series ultrasonic integrated press system
Hide thumbs Also See for i220:
Table of Contents

Advertisement

Compressed Air Requirements

For all press/thruster models, Dukane recommends 60-110 psi of clean, dry air.
Maximum available clamping pressure:
Model
Force Generated at
110 psi (lb)
20122XC0P3
Table 11- III
Clamping Pressure

AC Power Requirements

The AC line voltage and current needed depend on whichever press has been chosen for your
system. See the table below.
Operating
Press
Model Number
Frequency
20kHz
20122XC0P3
20kHz
20121XC0P3
20kHz
20122XC0P5
20kHz
20121XC0P5
20kHz
20242XC0P3
20kHz
20242XC0P5
Table 11- IV

AC Power Requirements

NOTES:
An X used above in the Model Numbers is a "wildcard" character meaning any valid character code combination.
Maximum line current requirement is specified at the minimum nominal AC line voltage and the rated power level.
Dukane Manual Part No. 403-594-02
Standard Air Cylinder
Diameter (in)
540
Overload
Power
Ratings
(Watts)
1200
1200
1200
1200
2400
2400
2.50
Input AC Power Requirements
Nominal AC Volt
@ Maximum RMS Current
100-120V 50/60 Hz @ 15 Amps
200-240V 50/60 Hz @ 8 Amps
100-120V 50/60 Hz @ 15 Amps
200-240V 50/60 Hz @ 8 Amps
200-240V 50/60 Hz @ 15 Amps
200-240V 50/60 Hz @ 15 Amps
Never operate the generator
at voltages lower than 100V .
Current will exceed the rating
and cause a shock hazard .
Section 11 - Specifications
NOTE
A representative model was
used in the compressed air re-
quirements table. Your model's
force and air cylinder diameter
may vary somewhat from what
is shown here.
North America/
Japan
AC Outlet Rating
15 Amps
WARNING
Page 109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents