Mitsubishi Electric MR-J4-_GF Instruction Manual page 125

Melservo-j4 servo amplifier
Table of Contents

Advertisement

6. SERVO MOTOR DRIVING
2) During dwell
Servo motor speed
Target point table
Controlword bit 4
(New set-point)
Controlword bit 8 (Halt)
Status DO 5 bit 5
(S_CPO (Rough match))
INP/S_INP
(In-position)
Status DO 5 bit 6
(S_MEND (Travel completion))
Point actual value
(f) Suspension of point table operation
To suspend the point table operation or change the operation pattern, stop the servo motor with
"Controlword bit 8 (HALT)" and switch the control mode to Jog operation (jg) with "Modes of
operation". The remaining travel distance is cleared.
Servo motor speed
Target point table
Controlword bit 4
(New set-point)
Controlword bit 8 (Halt)
Modes of operation
Point table No. n
Forward
rotation
0 r/min
Reverse
rotation
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Point table No. n
Forward
rotation
0 r/min
Reverse
rotation
ON
OFF
ON
OFF
ON
OFF
Point table No. n + 1
Dwell = ta + tb
ta
tb
No. n
Remaining distance
No. n
-101 (pt)
6 - 66
No. n
Remaining distance clear
-100 (jg)
-101 (pt)