7. PARAMETERS
No./symbol/
Setting
name
digit
PT15
Set an address increasing side of the software stroke limit.
LMPL
The combination of the upper and lower digits makes one address.
Software limit
Set an address in hexadecimal.
+
(lower four
Setting address:
digits)
PT16
LMPH
Software limit
Setting the same value in "Software limit -" disables the software limit.
+
When setting this parameter with MR Configurator2, change the status to servo-off or the
(upper four
mode to the home position return mode.
digits)
The unit can be changed to 10
PT01].
Setting range: 0000h 0000h to FFFFh FFFFh
PT17
Set an address decreasing side of the software stroke limit.
LMNL
The combination of the upper and lower digits makes one address.
Software limit
Set an address in hexadecimal.
-
(lower four
Setting address:
digits)
PT18
LMNH
Setting the same value in "Software limit +" will disable the software stroke limit.
Software limit
-
When setting this parameter with MR Configurator2, change the status to servo-off or the
(upper four
mode to the home position return mode.
digits)
The unit can be changed to 10
PT01].
Setting range: 0000h 0000h to FFFFh FFFFh
PT19
Set an address increasing side of the position range output address.
The combination of the upper and lower digits makes one address. Using [Pr. PT19] to
*LPPL
[Pr. PT22], set a range in which Index 2D17h Status DO7 bit2 (Position range) turns on.
Position
range output
Setting address:
address +
(lower four
digits)
PT20
*LPPH
Position
range output
The unit can be changed to 10
address +
PT01].
(upper four
digits)
Setting range: 0000h 0000h to FFFFh FFFFh
Function
Upper four
Lower four
digits
digits
[Pr. PT15]
[Pr. PT16]
STM
[μm], 10
(STM-4)
Upper four
Lower four
digits
digits
[Pr. PT17]
[Pr. PT18]
STM
[μm], 10
(STM-4)
Upper four
Lower four
digits
digits
[Pr. PT19]
[Pr. PT20]
STM
[μm], 10
(STM-4)
7 - 19
[inch], or [pulse] with the setting of [Pr.
[inch], or [pulse] with the setting of [Pr.
[inch], or [pulse] with the setting of [Pr.
Control
Initial
mode
value
C
P
[unit]
P
S
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.