Mitsubishi Electric MR-J4-_GF Instruction Manual page 202

Melservo-j4 servo amplifier
Table of Contents

Advertisement

9. MANUFACTURER FUNCTIONS
3) Cam data start position
This is not used in the coordinate data type.
4) Timing of applying cam control data
New values are applied to "Cam No." when bit 5 of Control DI2 (2D02h) turns on.
"Cam standard position" is updated when the cam axis current value per cycle passes through
"0".
(3) List of cam control data
The following table lists the cam control data added for the simple cam function.
Set the cam control data in the cam data creation window of MR Configurator2.
No.
Symbol
1
MCYSM
Main shaft current value per cycle setting method
(Note)
2
CPRO
Cam axis position restoration target
(Note)
3
CBSSM
Cam standard position setting method
(Note)
4
CCYSM
Cam axis current value per cycle setting method
(Note)
5
MICYS
Main shaft current value per cycle initial setting value
(Note)
6
CIBSS
Cam standard position initial setting value
(Note)
7
CICYS
Cam axis current value per cycle initial setting value
(Note)
8
For manufacturer setting
9
10
11
12
13
14
*ETYP
Synchronous encoder axis unit
15
*ECMX
Synchronous encoder axis unit conversion numerator
16
*ECDV
Synchronous encoder axis unit conversion denominator
POINT
Once the servo amplifier is powered off, the temporarily written data will be
deleted. To store the temporarily written data, be sure to write it to the Flash-
ROM before powering off the servo amplifier.
To enable the cam control data whose symbol is preceded by *, cycle the power
after setting. The cam control data is not applied by the temporal writing of MR
Configurator2.
Name
Initial
value
0
0
0
0
0
0
0
0
0
0
0
0
0
0000h
0
0
9 - 17
Operation mode
Unit
[µm]/
10
-4
[inch]/
10
[degree]/
-3
[pulse]
[µm]/
10
-4
[inch]/
[pulse]
[μm]/
10
-4
[inch]/
10
[degree]/
-3
[pulse]
Control
mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4-_gf_rj

Table of Contents