Mitsubishi Electric MR-J4-_GF Instruction Manual page 179

Melservo-j4 servo amplifier
Table of Contents

Advertisement

7. PARAMETERS
No./symbol/
Setting
name
digit
PN22
_ _ x x
Operation specification IP address 2
**IPOAA
Set the 2nd octet of the IP address of the network device allowed to be connected in
hexadecimal.
Operation
specification
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
IP address A
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
x x _ _
Operation specification IP address 1
Set the 1st octet of the IP address of the network device allowed to be connected in
hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
PN23
_ _ x x
Operation specification IP address 4
**IPOAB
Set the 4th octet of the IP address of the network device allowed to be connected in
hexadecimal.
Operation
specification
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
IP address B
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
x x _ _
Operation specification IP address 3
Set the 3rd octet of the IP address of the network device allowed to be connected in
hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
Function
7 - 30
Control
Initial
mode
value
C
P
[unit]
P
S
00h
00h
00h
00h