Setting Fieldbus - Omron ZW-C1*AT User Manual

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Steps
Key operation
13
Important
• The default gateway cannot be set from the Sensor Controller.
• To enable the settings, restart the Sensor Controller.

Setting Fieldbus

Network Settings of the Sensor p.203
Operating procedure
Steps
Key operation
1
2
3
4
5
6
ZW User's Manual
Display
Description
Press the
Display
Description
Press and hold the
Press the
Press the
Press the
Select the Fieldbus.
E-CAT: EtherCAT communications
EIP: EtherNet/IP communications
OFF: OFF
The current setting value is displayed on the sub-display.
Press
Select "EIP" and press the
Press the
key for two seconds to enter the RUN mode.
key for two seconds to enter the FUN mode.
/
keys to select "SYSTEM" and press the
/
keys to select "COM" and press the
/
keys to select "MEMLNK" and press the
/
key to enter editing mode and the sub-display blinks.
key.
key for two seconds to enter the RUN mode.
Connecting with EtherNet/IP
key.
key.
key.
351