Event name
Bank data error
Meaning
The bank data saved to the displacement sensor is corrupt.
Source
EtherCAT master function module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The displacement sensor power
was turned OFF during saving/
loading of bank data.
Attached
None
information
Precautions/
None
Remarks
Event name
Ethernet communication parameter error
Meaning
An invalid IP address is set for the displacement sensor.
Source
EtherCAT master function module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
Invalid IP address setting
Attached
None
information
Precautions/
None
Remarks
276
Error Messages
Source details
Minor fault
Recovery
Continues
Operation
EtherCAT NET ERR
Data type
Correction
After holding down the Mode
switching key, press the ZERO/SET
key to clear the system settings and
the bank data, then resume the
starting process.
Source details
Minor fault
Recovery
Continues
Operation
EtherCAT NET ERR
Data type
Correction
Change to the correct IP address.
Event code
14B30000Hex
Slave
Detection
timing
Error reset
Log category
(after
cancellation of
slave error)
An error message is displayed on the displacement
sensor's digital display, and the ALARM output of
parallel I/O turns ON. The displacement sensor is in a
stopped state until it is restarted.
EtherCAT LINK/ACT
Name
Prevention
Do not turn the displacement
sensor OFF during saving/loading
of bank data.
Event code
2481 0000Hex
Slave
Detection
timing
Error reset
Log category
(after
cancellation of
slave error)
An error message is displayed on the displacement
sensor's digital display, and the ALARM output of
parallel I/O turns ON. The displacement sensor is in a
stopped state until it is restarted.
EtherCAT LINK/ACT
Name
Prevention
Do not set an invalid IP address
such as "0.0.0.0".