Omron ZW-C1*AT User Manual page 169

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

I/O port name
Signal
Command
Command code
Command Parameter 1
Parameter 1-3
to 3
Note
• In the FUN mode, control signals other than ERCLR and LIGHTOFFx cannot be executed.
• Multiple control signals cannot be executed in the same cycle. Note, however, that when zero reset execution/
cancellation are performed simultaneously on multiple tasks, ZEROx_T1 to 4 and ZEROCLRx_T1 to 4 can be
executed in the same cycle. Also, all control signals can be executed in the same cycle on ERCLR and
LIGHTOFFx.
• When the status of control signals differs from that of the input status of parallel I/O, processing is executed of one
of the statuses is ON.
• SYNC can be used only in EtherCAT communications. It cannot be used in EtherNet/IP communications.
● I/O ports of response area
Displacement sensor (slave)  Controller (master)
I/O port name
Signal
Common Status Flag
FLG
FLG
SYNCFLG
SYNCFLG
READY
READY
RUN
RUN
ERR
ERR
BANKOUT1_A to E
BANKOUT1_A to E
ZW User's Manual
Signal name
Function
Command code
Stores the command code.
Command parameter
Stores the command parameter.
Signal name
Function
Sensor head common
status signal
Control command
Turns ON when the displacement sensor completes
completion
control command execution.
(Turns ON after the control command code, response code
and response status are stored.)
Automatically turns OFF if the control command execution
signal (EXE signal) from the user (Controller) turns OFF.
Measurement
Turns ON when the displacement sensor executes
synchronization
measurement synchronization processing and the state
completion
changes to one where normal measured values can be
output.
Automatically turns OFF if the measurement
synchronization signal (SYNC signal) from the user
(Controller) turns OFF.
Ready
Turns OFF when the displacement sensor cannot execute
control commands or measurement synchronization
processing.
Turns ON when the displacement sensor can execute
control commands or measurement synchronization
processing.
Run screen
Turns ON when the displacement sensor is in the RUN
mode.
Turns OFF when the displacement sensor is in the FUN
mode.
Error
Turns ON when a displacement sensor error is detected.
Turns OFF when the displacement sensor is normal.
After it turns ON, it never turns OFF until the error clear
signal (ERCLR signal) from the user (Controller) turns ON.
Current bank number
This outputs the currently specified bank number.
It expresses the bank number in combinations of
BANKOUTx_A to E.
(For details of combinations, see
Note
.)
EtherCAT Connection
167