Non-measurement
I/O setting
[I/O]
[HLD.RST]
Judgment
[JUDGE]
Analog output
[ANALOG]
*
The same "OUTPUT" is set for all banks. The output destination cannot be set separately for individual banks.
290
Search from Menu Tree
setting
Output target
[OUTPUT]
Hysteresis
[HYS]
Timer
[TIMER]
Output
*
destination
[V OR C]
Output target
[OUTPUT]
Monitor focus
[FOCUS]
Calibration
[CALIB]
Setting
Option/Setting Range
Non-measurement
setting
Keep [KEEP]/Clamp [CLAMP]
[HLD.RST]
Current output: MIN [MIN]
(approx. 3.4 mA)/4mA/5mA/..../19mA/
20mA/MAX [MAX]
Analog
(approx. 21mA) (default value: MAX)
output
Voltage output: MIN [MIN]
[ANALOG]
(approx. -10.8V)/-10V/-9V/.../9V/10V/
MAX [MAX] (approx. 10.8V)
(default value: MAX)
*
Output target
TASK1 [TASK1]
/TASK2 [TASK2]/
[OUTPUT]
TASK3 [TASK3]/TASK4 [TASK4]
0 to 99.9999 mm
Hysteresis
(default value: 0.05% of measuring
[HYS]
range)
*
TIMER
Off
[OFF]/Off delay [OFF.DLY]/
[TIMER]
On delay [ONDLY]/One shot [1SHOT]
Timer time
1 to 5000 ms (default value: 1)
[TIME]
Output
*
destination
Voltage output
/Current output
[V OR C]
Off [OFF]/TASK1 [TASK1]
Output target
TASK2 [TASK2]/TASK3 [TASK3]/
[OUTPUT]
TASK4 [TASK4]
Focus
*
Off [OFF]
/On [ON]
[FOCUS]
Focus
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
current/
16/17/18/19/20mA (default value: 4mA)
voltage 1
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
[CUR1]/
0/1/2/3/4/5/6/7/8/9/10V
[VOLT1]
(default value: -10V)
Measurement
-999.999999 to 999.999999 mm
value 1
(default value: -0.5)
[MEAS1]
Focus
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
current/
16/17/18/19/20mA (default value: 20mA)
voltage 2
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
[CUR2]/
0/1/2/3/4/5/6/7/8/9/10V
[VOLT2]
(default value: 10V)
Measurement
-999.999999 to 999.999999 mm
data2
(default value: 0.5)
[MEAS2]
Calibration
*
Off
/On
[CALIB]
Calibration
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
current/
16/17/18/19/20mA (default value: 4mA)
voltage 1
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
[CUR1]/
0/1/2/3/4/5/6/7/8/9/10V
[VOLT1]
(default value: -10V)
Calibration
value 1
-999 to 999 (default value: 0)
[ADJ1]
Calibration
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
current/
16/17/18/19/20mA (default value: 20mA)
voltage 2
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
[CUR2]/
0/1/2/3/4/5/6/7/8/9/10V
[VOLT2]
(default value: 10V)
Calibration
value 2
-999 to 999 (default value: 0)
[ADJ2]