Omron ZW-C1*AT User Manual page 97

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Setting the Average Filter
Output measured data as the average value of a preset count.
Set this, for example, to ignore sudden changes in measured value.
Item
Setting item
Average number
Average
of times
 Explorer pane
 Edit pane
 Task Settings window : [Filter]
1
Select how many times the latest measured
values are to be averaged before output from
[Average number of times] - [Average].
Important
When measurement is started, the measurement result is not updated and output until the measured values have
been sampled for the preset average count.
Note
The average filter can also be set by the operating keys on the Sensor Controller.
Setting the Average Filter p.311
ZW User's Manual
Setting value
1/2/4/8/16/32/64/128/
256 (default value)/512/
1024/2048/4096 [times]
: [Bank] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Description
Switches the average count.
)
Setting the Output Conditions
95

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t

Table of Contents