Omron ZW-C1*AT User Manual page 226

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

● Measurement LED out
Command
LIGHTOFFx input
Area
Response
LIGHTx output
area
(1) The Controller changes the state of the LIGHTOFFx input signal from OFF to ON. At the rising edge of the
LIGHTOFFx input signal, the displacement sensor turns the measurement LED out.
(2) At measurement LED out, the displacement sensor changes the state of the LIGHTx output signal from ON
to OFF.
(3) The Controller turns the state of the LIGHTOFFx input signal from ON to OFF. At the falling edge of the
LIGHTOFFx input signal, the displacement sensor lights the measurement LED.
(4) At measurement LED on, the displacement sensor returns the LIGHTx output signal to ON.
● Zero reset execution/zero reset cancel
ZEROx input
Command
Area
ZEROCLRx input
Response
ZEROSTATx
area
output
(1) The Controller changes the state of the ZEROx_T1 to 4 input signals from OFF to ON. The displacement
sensor makes sure that ZEROx_T1 to 4 input signals have turned ON, and then executes the zero reset.
(2) At execution of zero reset, the displacement sensor changes the state of the ZEROSTATx_T1 to 4 output
signal from OFF to ON.
(3) The Controller makes sure that the ZEROSTATx_T1 to 4 output signals have turned ON, and then returns
the ZEROx_T1 to 4 input signals to OFF.
(4) The Controller changes the state of the ZEROCLRx_T1 to 4 input signals from OFF to ON. The
displacement sensor makes sure that ZEROCLRx_T1 to 4 input signals have turned ON, and then executes
the zero reset cancel.
(5) At the zero reset cancel, the displacement sensor returns the ZEROSTATx_T1 to 4 output signals to ON.
(6) The Controller makes sure that the ZEROSTATx_T1 to 4 output signals have turned OFF, and then returns
the ZEROCLRx_T1 to 4 input signals to OFF.
224
EtherNet/IP Connection
ON
OFF
ON
OFF
(1)
(2)
ON
OFF
ON
OFF
ON
OFF
(1)
(2) (3)
(3)
(4)
(4)
(5)
(6)