8-1 Error Messages

Errors for EtherCAT Connection (Sysmac Error Status)

The Sysmac Studio Standard Version displays errors that occur in the EtherCAT system (including Sensor
errors) as Sysmac error status.
Sysmac Error Status Table
This section provides a table of Sysmac error status that is related to the Sensor and describes the event
codes.
Event levels are given as following in the tables.
Abbreviation
Maj
Major fault level
Prt
Partial fault level
Min
Minor fault level
Obs
Observation
Info
Information
A version in parentheses in the Event code column is the unit version of the CPU Unit when the event was
added.
Refer to the NJ-series Troubleshooting Manual (Cat. No. W503) for all NJ-series event codes.
Event Code
Event name
04D00000Hex
Hardware error Some abnormality
ALARM
14B00000 Hex
Linearity
correction data
ALARM
error
14B10000 Hex
Linearity
correction data
ALARM
read error
14B20000 Hex
System setting
error
ALARM
14B30000 Hex
Bank data error The bank data saved
ALARM
24810000 Hex
Ethernet
communication
ALARM
parameter
error
74900000 Hex
Multiple control
signal input
error
270
Error Messages
Name
Meaning
• Hardware damage
occurred on the
displacement sensor
hardware.
The linearity
• Calibration ROM damage
correction data of the
displacement sensor
is damaged.
Reading of the
• Calibration ROM not inserted
displacement sensor
• Calibration ROM damage
linearity correction
data was not executed
correctly.
The system settings
• The displacement sensor
saved to the
displacement sensor
are corrupt.
• The displacement sensor
to the displacement
sensor is corrupt.
An invalid IP address
• Invalid IP address setting
is set for the
displacement sensor.
Multiple control
Multiple control signals turned
signals turned ON in
ON in the same cycle.
the same cycle.
Assumed cause
Maj
power was turned OFF dur-
ing saving/loading of system
settings.
power was turned OFF dur-
ing saving/loading of bank
data.
Level (*1)
Reference
(Pages)
Prt
Min
Obs
Info
p.274
p.274
p.275
p.275
p.276
p.276
p.277
ZW User's Manual