Omron ZW-C1*AT User Manual page 218

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

4
Network Configurator Settings
(1) Import to the Network Configurator the CSV file that you exported from the Sysmac Studio.
The variables that are imported will automatically be registered as tags.
(2) Set the connections as shown in the following table.
Originator device (PLC) settings
Input tag set: EIP Input
Output tag set: EIP Output
5
Accessing the Communications Areas from the User Program
The defined variables are used to access the communications areas for the Sensor using the following
notation.
• Command Area
Signal name
EXE
ERCLR
TIMING1
RESET1
LIGHTOFF1
ZERO1_T1
ZERO1_T2
ZERO1_T3
ZERO1_T4
ZEROCLR1_T1
ZEROCLR1_T2
ZEROCLR1_T3
ZEROCLR1_T4
Command code
Command parameter 1
Command parameter 2
Command parameter 3
216
EtherNet/IP Connection
Target device (Sensor) settings
Output tag set: Input101
Input tag set: Output100
Variable name
EIPOutput.CommonControlFlag.F[0]
EIPOutput.CommonControlFlag.F[16]
EIPOutput.SensorHead1ControlFlag.F[0]
EIPOutput.SensorHead1ControlFlag.F[1]
EIPOutput.SensorHead1ControlFlag.F[2]
EIPOutput.SensorHead1ControlFlag.F[16]
EIPOutput.SensorHead1ControlFlag.F[17]
EIPOutput.SensorHead1ControlFlag.F[18]
EIPOutput.SensorHead1ControlFlag.F[19]
EIPOutput.SensorHead1ControlFlag.F[20]
EIPOutput.SensorHead1ControlFlag.F[21]
EIPOutput.SensorHead1ControlFlag.F[22]
EIPOutput.SensorHead1ControlFlag.F[23]
EIPOutput.CommandCode
EIPOutput.CommandParam1
EIPOutput.CommandParam2
EIPOutput.CommandParam3
ZW User's Manual