Sensor Controller - Omron ZW-C1*AT User Manual

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Sensor controller

Specifications
Item
Input/output type
Number of connected sensor heads
Sensor head compatibility
Light source for measurement
Segment
Main display
Display
Sub-display
LED display
Status indicators
EtherCAT indicator
External I/F
Ethernet
EtherCAT
RS-232C
Analog
output
terminal
block
32-pole
expansion
connector
370
Specifications and External Dimensions
Specifications
ZW-CE10T
NPN
1
Available
White LED
11-segment red display, 6 digits
11-segment green display, 6 digits
HIGH (orange), PASS (green), LOW (orange), STABILITY (green), ZERO
(green), ENABLE (green), THRESHOLD-H (orange), THRESHOLD-L
(orange), RUN (green)
ECAT RUN (green), L/A IN (Link/Activity IN) (green), L/A OUT (Link/Activity
OUT) (green), ECAT ERR (red)
100BASE-TX/10BASE-T
EtherCAT exclusive protocol 100BASE-TX
Max. 115,200 bps
-10 V to +10 V, output impedance: 100 
Analog voltage output
(OUT 1 V)
4 mA to 20 mA, max. load resistance: 300 
Analog current output
(OUT 1 A)
Judgment output
Transistor output system
(HIGH 1/PASS 1/LOW 1)
Output voltage: 21.6 to 30 VDC
Load current: 50 mA or less
Busy output (BUSY 1)
Residual voltage when turning ON: 1.2 V or less
Leakage voltage when turning OFF: 0.1 mA or less
Alarm output (ALARM)
Enable output
(ENABLE 1)
LED OFF input
DC input system
(LED OFF 1)
Input voltage: 24 VDC ± 10% (21.6 to 26.4 VDC)
Input current: 7 mA Type. (24 VDC)
Zero reset input
ON voltage/ON current: 19 V/3 mA or less
(ZERO 1)
ON voltage/ON current: 5 V/1 mA or less
Timing input (TIMING 1)
Reset input (RESET 1)
Logging input (LOG-
GING)
Bank
Currently
Transistor output system
selected
Output voltage: 21.6 to 30 VDC
bank output
Load current: 50 mA or less
(BANK_OUT
Residual voltage when turning ON: 1.2 V or less
1 to 3)
Leakage voltage when turning OFF: 0.1 mA or less
Bank
DC input system
Selection
Input voltage: 24 VDC ± 10% (21.6 to 26.4 VDC)
input
Input current: 7 mA Type. (24 VDC)
(BANK_SEL
ON voltage/ON current: 19 V/3 mA or more
1 to 3)
OFF voltage/OFF current: 5 V/1 mA or less
ZW-CE15T
PNP
ZW User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t

Table of Contents