Tag Data Link Setting Methods

This section describes how to set data links for EtherNet/IP.
The communications areas in the PLC for which data links are created to the Sensor are specified as tags and
tag sets, and the connections are set for tag data link communications.
Tags, tag sets, and connections are set from the Network Configurator.
Refer to the following manuals for details on the tag data link settings that are made with the Network
Configurator.
• NJ-series CPU Unit Built-in EtherNet/IP Port User's Manual (Cat. No. W506)
• CS/CJ-series EtherNet/IP Units Operation Manual (Cat. No. W465)
• CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (Cat. No. W495)
Important
• To connect the ZW to an NJ/CJ-series CPU Unit, install the EDS file that defines the connection information for the
ZW in the Network Configurator. Download the EDS file from the OMRON website.
• After tag data links are set, the Displacement Sensor will automatically be restarted to enable the settings.
Tags, Tag Sets, and Connection Settings
The communications areas in the PLC are set as tag data link connections as shown in the following table.
• Tag and Tag Set Settings in the PLC
Parameter
Settings
Command area
Type of tags and tag set
Output tag set
Tag and tag set names
I/O memory addresses or variable names
Data size
24 bytes
*1
Specify the I/O memory address of the first word in the response area.
The output area is assigned immediately after the response area.
If you specify a variable name, the variable is assigned for both the response area and output area.
Refer to Accessing Communications Areas Using Variables with NJ-series Controllers on p. 213 for information on how to access the
signals in the communications areas from the user program when variables are assigned.
ZW User's Manual
Response area and output area
Input tag set
I/O memory addresses or variable names
56 bytes (total size of response area and output area)
EtherNet/IP Connection
*1
205