ACTION
Press the key
to go to the next
parameter
Press the key
programming mode
Use the keys
and
select the thermal motor protection
class
Press the key
selected option and exit the
programming mode
Press the key
to go to the next
parameter
72
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
HMI LED DISPLAY
HMI LCD DISPLAY
Ther.Prot.Class
P640=Class 30
to enter the
Ther.Prot.Class
P640=Class 30
to
Ther.Prot.Class
P640=Class 30
to save the
Ther.Prot.Class
P640=Class 30
Open the input circuit-breaker to disconnect the Soft-Starter SSW-06.
NOTE!
Repeat the first power-up process:
If you want to repeat the first power-up routine, set parameter P204 = 5
(it loads the factory standard default parameters), then follow the first
power-up routine;
The first power-up routine, as decribed above, automatically sets some
parameters automatically to the factory default. For more details, refer
to Chapter 6.
Soft Starter
ready
DESCRIPTION
Thermal motor Protection Class:
0= Inactive
1= Class 5
2= Class 10
4= Class 20
5= Class 25
6= Class 30
7= Class 35
8= Class 40
9= Class 45
Enter the programming mode.
Thermal motor protection class:
6= Class 30
(According to the motor data)
Exit the programming mode
Soft-Starter is reset
Soft-Starter is ready for operation