CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
Parameter
P277
(1)
RL1 Relay Output
Function
P278
(1)
RL2 Relay Output
Function
(1)
P279
RL3 Relay Output
Function
102
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Range
[Factory Setting]
Unit
Description / Notess
 Check the available options in Table 6.26.
0 to 9
 The status of the digital outputs can be monitored in the Parameter
[ 1=in
Operation ]
P013.
 The digital output will be enabled when the function which has been
-
programmed for the digital output is true.
0 to 9
[ 2=at Full
Voltage ]
-
0 to 9
[ 6=No
Fault ]
-
 "Not used" = the digital outputs are disabled.
 "In Operation" = the output will be enabled instantly with the Soft-Starter
SSW-06 Enable command, and will only be disabled when the
Soft-Starter SSW-06 receives the command Disable, or when the end
of the deceleration ramp is reached, if programmed.
 "Full Voltage" = the output will be enabled when the Soft-Starter
SSW-06 reaches 100% Un and it will be disabled when the Soft-Starter
SSW-06 receives the command Disable.
 "External By-pass" = its operation is similar to the "Full Voltage"
operation, but it must be applied only when the use of an external
By-pass contactor is required. See P140 and the recommended setup
at items 3.3 and 3.3.12.
 "FWD/REV-K1" = This operation is similar to the "In Operation", but it
must be enabled with forward motor direction of rotation. See P231
and the recommended setup at items 3.3 and 3.3.8.
 "FWD/REV-K2" = This operation is similar to the "In Operation", but it
must be enabled with reverse motor direction of rotation. See P231
and the recommended setup at items 3.3 and 3.3.8.
"DC-Braking" = The output will be enabled during the DC-Braking is
active. See P500 and the recommended setup at items 3.3 and 3.3.11.
The output will be enabled when DC-Braking is active. See P500 and
the recommended set-up at items 3.3 and 3.3.11.
DIx Parameter
DI1
Function
Not used
-
Enable/Disable
or Start
Stop (Three wires)
-
General Enable
-
FWD/VER REV
-
Local/Remote
-
No external Error
-
JOG
-
Brake Off
-
Error Reset
-
Motor Thermistor
-
Table 6.25 - Functions of the Digital Inputs
18
19
20
RL1
RL2
X1C
Figure 6.17 - Status of the relay digital outputs when disabled.
P264
P265
P266
P267
(DI2)
(DI3)
(DI4)
(DI5)
0
0
0
0
-
-
-
-
1
-
-
-
-
1
-
-
-
-
1
1
-
-
2
2
-
-
3
3
-
-
4
4
-
-
5
5
2
2
6
6
-
-
-
-
21
23
24
22
RL3
P268
(DI6)
0
-
-
-
1
2
3
4
5
6
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents