CHAPTER 3 - INSTALLATION AND CONNECTION
46
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
For signal and control wire installation, adopt the following
procedures:
1) The connections of the SSW-06 digital inputs can be carried out in
several ways. They can be supplied by auxiliary internal +24Vdc source
by using the 0V as a common point or by the +24Vdc source. Depending
on the application requirements,they can also be supplied by external
+24Vdc source , connected to PLCs, by using the 0V as common
point or by the +24Vdc source.:
Connector X1B
3
4
5
6
7
8
9
10 DGND
11
Figure 3.18 - Connection diagram of the digital inputs using an the auxiliary internal source
Connector X1B
3
4
5
6
7
+
8
9
24Vdc
10 DGND
11
Figure 3.19 - Connection diagram of the digital inputs using an external source
X1B
X1A
XO
To be used for grounding of shield of
the signal an control cables
Figure 3.17 - Control connector disposition
DI1
DI2
DI3
DI4
DI5
COM
COM
24Vdc
DI1
DI2
DI3
DI4
DI5
COM
COM
24Vdc
X1C
X2
X1D
Connector X1B
3
DI1
4
DI2
5
DI3
6
DI4
7
DI5
8
COM
9
COM
10 DGND
11
24Vdc
Connector X1B
3
DI1
4
DI2
5
DI3
6
DI4
7
DI5
8
COM
9
COM
+
10 DGND
24Vdc
11
24Vdc