Table 2 TBV Troubleshooting Descriptions
Issue
Banknote rejects
occur and the
Banknote
Acceptance Rate
is low. (The TBV
Bezel LED is
flashing GREEN.)
DIP S
WITCH
NOTE: The following DIP Switches are not shown in Figure 1:
DS3 - On front of Transport
DS7 - On Cash Box
NOTE: DIP Switch DS6 Memory Selection Switch is not used.
© 2019 JCM Global Corporation
TBV™-100/101 Units
Probable Cause
The Firmware
version is old.
Banknotes require
proper denomination
from the specific
country's Firmware
being validated.
Foreign objects are
adhering to the
sensors.
Need to perform
Sensor Calibration.
(Did not perform
Sensor Calibration
after the Unit's
disassembly or
repair.)
S
ETTINGS
Figure 1 TBV DIP Switch Locations
Possible Solutions
Confirm the required denomination
and/or issued year is correct by
referring to the specific Country's
Software Information Sheet.
Clean the Sensors.
Identify the LED Error flashing
pattern and locate the error (refer to
the Error Code Tables). Then
perform the necessary action
required. Perform a Validation Test.
4
Part No. 960-000207R_Rev. A