Calibration; When To Calibrate; Calibration Preparation; Reference Paper Usage - JCM GLOBAL VEGA Series Operation And Maintenance Manual

Table of Contents

Advertisement

Section 6

Calibration

This section provides instructions for performing a
calibration of the VEGA Sensors.
Before performing Sensor
NOTE:
Calibration, clean the Sensors to ensure
calibration accuracy (See "Sensor and
Roller Cleaning Procedure" on page 2-5).

When to Calibrate

Calibration should be performed when one of the
following conditions occur:
1. When removing one of the Circuit Boards
2. When the Banknote Acceptance Rate becomes
drastically degraded

Calibration Preparation

Figure 6-13 illustrate Tool and Harness Connection
to calibrate a VEGA Unit.
Confirm that the interconnection for performing the
VEGA calibration with the PC referring the illus-
tration shown in Figure 6-13.

Figure 6-13 Tool and Harness Connection

b
e
To PC USB Port
Interface Connector
Receptacle
g h
f
To AC Power
a) VEGA Unit
b) PC
(OS: Windows XP/7/8)
c) Power Supply
(following Electrical Specification)
d) USB Cable
d
) USB A Terminal
1
d
) USB Mini B Terminal
2
e) Adjustment Program
f) Harness
g) White Reference Paper KS-325
h) Black Reference Paper KS-326
Figure 6-13 Tool and Harness Connection
NOTE: Be sure to use the correct input
voltage for each Product Specification.
P/N 960-100189R_Rev. 4 {EDP #148850}
VEGA™ Series Banknote Validator
d
1
d
VEGA USB
Connector
d
2
a
c

Reference Paper Usage

This portion provides information concerning the
KS-325 White Reference Paper and the KS-326
Black Reference Paper settings and uses.

Figure 6-14 Reference Paper Types

KS-325
Figure 6-14 Reference Paper Types
Calibration using the White and Black Reference
Paper requires the same procedure. Perform the fol-
lowing steps to calibrate the VEGA Unit using the
individual calibration papers.
1. Press in on the Upper Transport Unit's left and
right side Open/Close Buttons (Figure 6-15 a),
and lift the Upper Transport Unit open (Figure 6-
15 b).

Figure 6-15 Upper Transport Unit Open

Figure 6-15 Upper Transport Unit Open
2. Insert the Black Sponge Portion of the Reference
Paper (Figure 6-16 a) into the Bezel Guide's
opening (Figure 6-16 b) allowed for the Sponge
width (Approximately 5mm); then align the lower
part of each Sponge to the edge of the Bezel
Guide (Figure 6-16 c).
NOTE: Do not cover the Entrance
Sensor (Figure 6-16 d) with the
Reference Paper. If the Reference
Paper covers any part of the
Entrance Sensor, calibration will not
be performed correctly.
However, when placing the Black
Reference Paper, a part of the black
portion covers the Entrance Sensor.
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 4
Calibration and Testing
KS-326
a b