Environmental Specifications; Electrical Specifications; Structural Specifications - JCM GLOBAL VEGA Series Operation And Maintenance Manual

Table of Contents

Advertisement

General Information

Environmental Specifications

Operating Temperature:
Storage Temperature:
Relative Operating Humidity:
Relative Storage Humidity:
Visible Light Sensitivity:
Installation:
*. Depends on Hydrothermal conditions
Hydrothermal Condition Graph
Allowable 
Operating
Temperature and
Humidity Range

Electrical Specifications

* †
Supply Voltage
:
Current Consumption
*. If Voltage ripple exists on the applied Voltage, ensure that the minimum Voltage does not fall below 20V DC, and filter the Voltage ripple smooth as
much as possible. Hot-swapping is prohibited (e.g., do not plug or unplug Power Connectors while the power is active [ON]).
†. Be sure that the electrical specification for the VEGA Unit matches the optional VEGA-RC Unit (e.g., The VEGA-RC 12V DC Specification Unit must
be installed on the VEGA 12V DC Specification Unit and the VEGA-RC 24V DC Specification Unit must be installed on the VEGA 24V Specification
Unit).
‡. Each Current Consumption is for only the VEGA Unit. When using the VEGA Unit with the VEGA-RC, refer to the Section 1 "Electrical Specification"
of the VEGA-RC Operation and Maintenance Manual and add the VEGA and the VEGA-RC Current Consumption.

Structural Specifications

Weight:
*
Mounting:
Cash Box Limit Stop:
Outer Dimensions:
*. Both vertical and transverse types should be installed at 90 degrees to the Frame.
†. Without a 12mm width Faceplate.
P/N 960-100189R_Rev. 4 {EDP #148850}
VEGA™ Series Banknote Validator
Table 1-4 VEGA Environmental Specifications
0°C to + 50°C (32°F to 122°F)
-20°C to + 60°C (- 4°F to 140°F)
30% to 80% RH (non-condensed)
10% to 85% RH (non-condensed)
Avoid contact with direct sunlight (
Angle of 15 Degree or more, having an Illumination index of 3000 Lux or less
Indoors Only (
35
50
Table 1-5 VEGA Electrical Specifications
12V DC (±5%)
24V - 36V DC (Range: 20V - 42.5V DC) Option
Standby = 0.2A (12V DC)
Operation = 0.7A (Max:1.0A) (12V DC)
Option: Standby = 0.1A (24V DC)
:
Operation = 0.5A (Max: 0.6A) (24V DC)
Standby = 0.1A (36V DC)
Operation = 0.3A (Max: 0.5A) (36V DC)
Table 1-6 VEGA Structural Specifications
Unit (300 notes): Approximately 2kg (4.409 lbs)
Unit (1000 notes): Approximately 2.5kg (5.516lbs)
Cash Box (300 notes): Approximately 0.8kg (1.763 lbs)
Cash Box (1000 notes): Approximately 1kg (2.204 lbs)
Horizontal (SH Type)
Vertical Surface Installation (SU/SD Type)
a) Rear Installation (Front Access) (SHF Type)
b) Front Installation (Rear Access) (SHR Type)
168mm (6.61 in) High x 221.5mm (8.72 in) Deep x 104mm (4.09 in)
Wide.
*
*
Interior lighting must be incandescent with a Gradient
Not exposed to the elements, including the internal Unit assemblies
°
C/80RH%
°
C/30RH%
© 2016, JAPAN CASH MACHINE CO., LTD.
1 - 7
Section 1
)
)

Hide quick links:

Advertisement

Table of Contents
loading